Part No. | Inductance | Test Freq. | DCR(mΩ) | Isat(A) | Irms(A) | Tolerance | Marking |
(μH) | Max | Typ.(Max) | Typ.(Max) | (±%) | |||
HCNR4026-1R2□ | 1.2 | 100kHz,1V | 36 | 3.50(3.15) | 3.30(2.97) | 30 | 1R2 |
HCNR4026-3R3□ | 3.3 | 100kHz,1V | 104 | 2.50(2.25) | 2.50(2.25) | 20,30 | 3R3 |
HCNR4026-4R7□ | 4.7 | 100kHz,1V | 120 | 1.80(1.62) | 1.80(1.62) | 20,30 | 4R7 |
HCNR4026-220□ | 22 | 100kHz,1V | 440.4 | 0.86(0.77) | 1.00(0.90) | 20,30 | 220 |
NOTE: □-tolerance M=±20% / T=±30% | |||||||
1.Operating temperature range -40℃~125℃(Including self – temperature rise) | |||||||
2.Isat for Inductance drop 30% from its value without current. | |||||||
3.Irms for a 40℃ temprature rise from 25℃ ambient. | |||||||