Part No. | Inductance | Test Freq. | DCR(Ω) | Rated Current | Tolerance | Marking |
(μH ) | Max. | (A) | (±%) | |||
HCRI4D18T-1R0□ | 1 | 7.96 MHz,1 V | 0.045 | 1.72 | 30 | 1R0 |
HCRI4D18T-1R5□ | 1.5 | 7.96 MHz,1 V | 0.06 | 1.5 | 30 | 1R5 |
HCRI4D18T-1R8□ | 1.8 | 7.96 MHz,1 V | 0.07 | 1.35 | 30 | 1R8 |
HCRI4D18T-2R2□ | 2.2 | 7.96 MHz,1 V | 0.075 | 1.32 | 30 | 2R2 |
HCRI4D18T-2R7□ | 2.7 | 7.96 MHz,1 V | 0.105 | 1.28 | 30 | 2R7 |
HCRI4D18T-3R3□ | 3.3 | 7.96 MHz,1 V | 0.11 | 1.04 | 30 | 3R3 |
HCRI4D18T-3R9□ | 3.9 | 7.96 MHz,1 V | 0.155 | 0.88 | 30 | 3R9 |
HCRI4D18T-4R7□ | 4.7 | 7.96 MHz,1 V | 0.162 | 0.84 | 30 | 4R7 |
HCRI4D18T-5R6□ | 5.6 | 7.96 MHz,1 V | 0.17 | 0.8 | 30 | 5R6 |
HCRI4D18T-6R3□ | 6.3 | 7.96 MHz,1 V | 0.18 | 0.78 | 30 | 6R3 |
HCRI4D18T-6R8□ | 6.8 | 7.96 MHz,1 V | 0.2 | 0.76 | 30 | 6R8 |
HCRI4D18T-8R2□ | 8.2 | 7.96 MHz,1 V | 0.245 | 0.68 | 30 | 8R2 |
HCRI4D18T-100□ | 10 | 100 kHz,1 V | 0.28 | 0.61 | 20,30 | 100 |
HCRI4D18T-120□ | 12 | 100 kHz,1 V | 0.32 | 0.56 | 20,30 | 120 |
HCRI4D18T-150□ | 15 | 100 kHz,1 V | 0.36 | 0.5 | 20,30 | 150 |
HCRI4D18T-180□ | 18 | 100 kHz,1 V | 0.4 | 0.48 | 20,30 | 180 |
HCRI4D18T-220□ | 22 | 100 kHz,1 V | 0.48 | 0.41 | 20,30 | 220 |
HCRI4D18T-270□ | 27 | 100 kHz,1 V | 0.57 | 0.35 | 20,30 | 270 |
HCRI4D18T-330□ | 33 | 100 kHz,1 V | 0.694 | 0.32 | 20,30 | 330 |
HCRI4D18T-390□ | 39 | 100 kHz,1 V | 0.8 | 0.3 | 20,30 | 390 |
HCRI4D18T-470□ | 47 | 100 kHz,1 V | 0.95 | 0.28 | 20,30 | 470 |
HCRI4D18T-560□ | 56 | 100 kHz,1 V | 1.08 | 0.26 | 20,30 | 560 |
HCRI4D18T-680□ | 68 | 100 kHz,1 V | 1.3 | 0.24 | 20,30 | 680 |
HCRI4D18T-101□ | 100 | 100 kHz,1 V | 2 | 0.2 | 20,30 | 101 |
HCRI4D18T-151□ | 150 | 100 kHz,1 V | 2.84 | 0.15 | 20,30 | 151 |
NOTE: □-tolerance M=±20% / T=±30% | ||||||
1.Operating temperature range -40℃~125℃(Including self – temperature rise) | ||||||
2.Rate current: The rate current indicates the current when the inductance decreases to 65% over of | ||||||
it’s nominal value or D.C.current when the temperature rising △T=40℃ lower, whichever is lower. | ||||||
3.RDC test method: place testing device to the 2 solder ends of wounding and test the value. | ||||||