Part No. | Impedance | Test Freq. | DCR(Ω) | Rated current | Tolerance |
(Ω) | (MHz) | Max | (mA)Max | (±%) | |
HCTI201209U-7R0□ | 7 | 100 | 0.030 | 3000 | 25 / 30 |
HCTI201209U-100□ | 10 | 100 | 0.030 | 3000 | 25 / 30 |
HCTI201209U-110□ | 11 | 100 | 0.010 | 6000 | 25 / 30 |
HCTI201209U-170□ | 17 | 100 | 0.025 | 3000 | 25 / 30 |
HCTI201209U-200□ | 20 | 100 | 0.025 | 3000 | 25 / 30 |
HCTI201209U-260□ | 26 | 100 | 0.025 | 3000 | 25 / 30 |
HCTI201209U-300□ | 30 | 100 | 0.025 | 3000 | 25 / 30 |
HCTI201209U-400□ | 40 | 100 | 0.050 | 3000 | 25 / 30 |
HCTI201209U-470□ | 47 | 100 | 0.060 | 3000 | 25 / 30 |
HCTI201209U-600□ | 60 | 100 | 0.060 | 3000 | 25 / 30 |
HCTI201209U-700□ | 70 | 100 | 0.100 | 3000 | 25 / 30 |
HCTI201209U-800□ | 80 | 100 | 0.100 | 3000 | 25 / 30 |
HCTI201209U-101□ | 100 | 100 | 0.060 | 3000 | 25 / 30 |
HCTI201209U-121□ | 120 | 100 | 0.060 | 3000 | 25 / 30 |
HCTI201209U-151□ | 150 | 100 | 0.060 | 3000 | 25 / 30 |
HCTI201209U-181□ | 180 | 100 | 0.100 | 2000 | 25 / 30 |
HCTI201209U-221□ | 220 | 100 | 0.100 | 2000 | 25 / 30 |
HCTI201209U-301□ | 300 | 100 | 0.100 | 2000 | 25 / 30 |
HCTI201209U-471□ | 470 | 100 | 0.100 | 2000 | 25 / 30 |
HCTI201209U-601□ | 600 | 100 | 0.150 | 2000 | 25 / 30 |
HCTI201209U-102□ | 1000 | 100 | 0.300 | 1000 | 25 / 30 |
Note: When ordering, please specify tolerance code. Tolerance : Y=±25% , T=±30% | |||||
1.Operating temperature range-40℃~125℃(Including self – temperature rise) | |||||
2.Rate Current:Applied the current to coils, the temperature rise shall not be more than 40℃ | |||||