Part No. | Inductance | Test Freq. | DCR(mΩ) | Isat(A) | Irms(A) | Tolerance | Marking |
(μH) | Typ(Max) | Typ | Typ | (±%) | |||
HCUY0624A-R10□ | 0.10 | 100kHz,0.25V | 0.9(1.2) | 43.0 | 33.0 | 20,30 | R10 |
HCUY0624A-R22□ | 0.22 | 100kHz,0.25V | 2.4(3.0) | 34.0 | 21.0 | 20,30 | R22 |
HCUY0624A-R33□ | 0.33 | 100kHz,0.25V | 3.4(4.1) | 24.0 | 18.0 | 20,30 | R33 |
HCUY0624A-R47□ | 0.47 | 100kHz,0.25V | 6.0(6.5) | 21.0 | 13.5 | 20,30 | R47 |
HCUY0624A-R56□ | 0.56 | 100kHz,0.25V | 5.9(6.5) | 17.0 | 13.0 | 20,30 | R56 |
HCUY0624A-R68□ | 0.68 | 100kHz,0.25V | 6.0(7.2) | 16.0 | 12.0 | 20,30 | R68 |
HCUY0624A-R82□ | 0.82 | 100kHz,0.25V | 10.2(11.8) | 17.0 | 10.0 | 20,30 | R82 |
HCUY0624A-1R0□ | 1.0 | 100kHz,0.25V | 10.2(13.5) | 15.5 | 10.0 | 20,30 | 1R0 |
HCUY0624A-1R5□ | 1.5 | 100kHz,0.25V | 16.7(21.0) | 15.0 | 8.0 | 20,30 | 1R5 |
HCUY0624A-2R2□ | 2.2 | 100kHz,0.25V | 22(28) | 14.0 | 7.0 | 20,30 | 2R2 |
HCUY0624A-3R3□ | 3.3 | 100kHz,0.25V | 32(39) | 13.0 | 5.5 | 20,30 | 3R3 |
HCUY0624A-4R7□ | 4.7 | 100kHz,0.25V | 41(50) | 10.0 | 5.0 | 20,30 | 4R7 |
HCUY0624A-5R6□ | 5.6 | 100kHz,0.25V | 53(65) | 7.0 | 4.0 | 20,30 | 5R6 |
HCUY0624A-6R8□ | 6.8 | 100kHz,0.25V | 57(70) | 6.0 | 4.0 | 20,30 | 6R8 |
HCUY0624A-8R2□ | 8.2 | 100kHz,0.25V | 84.2(106) | 8.0 | 3.0 | 20,30 | 8R2 |
HCUY0624A-100□ | 10 | 100kHz,0.25V | 100(105) | 7.0 | 3.0 | 20,30 | 100 |
HCUY0624A-150□ | 15 | 100kHz,0.25V | 145(160) | 3.3 | 2.5 | 20,30 | 150 |
HCUY0624A-220□ | 22 | 100kHz,0.25V | 210(230) | 2.5 | 2.0 | 20,30 | 220 |
NOTE: □-tolerance M=±20% / T=±30%
1.Operating temperature range -40℃~125℃(Including self – temperature rise)
2.Isat for Inductance drop 30% from its value without current.
3.Irms for a 40℃ temprature rise from 25℃ ambient.
4.Product characteristics can be designed according to customer requirements