Part No. | Inductance | Test Freq. | DCR(mΩ) | Isat(A) | Irms(A) | Tolerance | Marking |
(μH) | Typ(Max) | Typ | Typ | (±%) | |||
HCUY120803C-R22□ | 0.22 | 100kHz,0.25V | 0.9(1.0) | 70.0 | 33.0 | 20,30 | R22 |
HCUY120803C-R47□ | 0.47 | 100kHz,0.25V | 1.7(2.0) | 42.0 | 24.0 | 20,30 | R47 |
NOTE: □-tolerance M=±20% / T=±30%
1.Operating temperature range -40℃~125℃(Including self – temperature rise)
2.Isat for Inductance drop 30% from its value without current.
3.Irms for a 40℃ temprature rise from 25℃ ambient.
4.Product characteristics can be designed according to customer requirements